Categories

Junction box PV GAK 202 PG

Characteristics
Generator boxes with preassembled surge protection:

Legend
a) type 1+2 GAK DIS 60 VGPVS-1000-4ST-2MPP
b) type 1+2 GAK DIS 50 PVS-1000-4ST-2MPP
c) type 1+2 GAK DIS 50 VGPVS-1000-4ST-2MPP
d) type 2 GAK DIS 50 PV-1000-4ST-2MPP

SPD type
T1 / T2  
Operation voltage max. [Uc]
≤1200VDC  
Number of poles
2  
Nominal line voltage Un DC
1000 V  
Protection level max. (at 5kA)
2.1 kV  
Protection level max. (at 12.5kA)
2.3 kV  
Operating current [Ic]
0 kA  
Follow current [IF]
0 kA  
Follow current [IF]
0 kA  
follow current extinguishing capability [Ifi]
Unendlich kA eff  
Fault indication
mechanisch, Rot  
Temperature range
-40.0 - 85.0
Fault indication
Mechanisch, Rot  
Temperature range
-40.0 - 85.0
Material housing
 
Signaling on the device
optisch  
Material housing
 
Signaling on the device
optisch  
Connection cross section solid / stranded max.
1.5 mm²  
Connection cross section solid / stranded max.
1.5 mm²  
Degree of protection
IP20  
Energetically coordinated protective effect to the terminal
Yes  
Energetically coordinated protective effect to the terminal
Yes  
System configuration DC
Yes  
Material housing
 
System configuration DC
Yes  
Signaling on the device
optisch  
Connection cross section solid / stranded max.
1.5 mm²  
Integrated backup fuse
No  
Exhausting
No  
Energetically coordinated protective effect to the terminal
Yes  
Integrated backup fuse
No  
Exhausting
No  
Mounting method
DIN rail (top hat rail) 35 mm  
System configuration DC
Yes  
Total discharge current (8/20) (L N-PE)
60 kA  
Integrated backup fuse
No  
Mounting method
DIN rail (top hat rail) 35 mm  
Degree of protection (IP)
IP20  
Integrated backup fuse
No  
Exhausting
No  
Exhausting
No  
Mounting method
DIN rail (top hat rail) 35 mm  
Total discharge current (8/20) (L N-PE)
60 kA  
Degree of protection (IP)
IP20  
Degree of protection (IP)
IP20  
degree of protection
IP65  
number of modules
20  
contract rail
DIN-Schiene  
String / MPP
4ST-2MPP  
inputs PG / MC4
PG  
outputs PG / MC4
PG  
Switching capacity voltage max. Uoc Max.
1000 V  
Switching current max. Isc. Max.
30 A  
Cross-sectional area
6 mm²  
Test standards USA
UL 1449 ed.3  
Homologation
VDE, ÖVE und UL  
Test standards Germany
 
Test standards France
UTE C61-740-51  
Test standards Germany
 
Test standards USA
UL 1449 ed.3  
Test standards France
UTE C61-740-51  
   
Article No. E-Number SPD type Operation voltage max. [Uc] Impulse current [Iimp]_(10/350) max. discharge current (Imax) Response time [ta] Voltage protection level [Up] Nominal cross section conductor (min/max) Signaling contact Nominal discharge surge current (8/20) Number of poles comment VPE Quantity
   
Junction box PVGAK DIS60VG-1000-4ST-2MPP PG 296.049.307 969 111 644 T1 / T2 ≤1200VDC 12.5 40 ≤25 2.8 6.0 - 35.0 Yes 20 2 a) 1
Junction box PV GAK DIS50 PVS-1000-4ST-2MPP 296.049.907 969 111 674 T1 / T2 ≤1200VDC 6.25 40 ≤25 2.6 2.5 - 25.0 Yes 15 2 b) 1
Junction box PV GAK DIS50VG-1000-4ST-2MPP 296.049.507 969 111 654 T1 / T2 ≤1200VDC 6.25 40 ≤25 2.8 2.5 - 25.0 Yes 2 c) 1
Junction box PVGAK DIS50-1000-4ST-2MPP PG 296.049.707 969 111 664 T2 ≤1200VDC 5 40 ≤25 2.6 2.5 - 25.0 Yes 15 2 d) 1